EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-009 
Page 24 of 26 
 
4.4
 
Disturbance Voltage at Antenna Terminal. 
 
4.4.1 Site and Test Description 
 
Testing was performed in accordance with CISPR 13. 
 
When measurements are made at the antenna terminals of the EUT, a signal generator shell be used to feed 
the EUT with a standard test signal.  
 
The Antenna Terminals  of the EUT and the Signal Generator are connected to the measuring receiver by 
means of coaxial cables and the resistive combining network having a minimum attenuation of 6 dB. 
 
The Impedance seen from the EUT shall be equal to the nominal Antenna input impedance for which the 
EUT has been designed. If the output impedance of the signal generator and the input impedance of the 
measuring receiver differ from the value, additional matching network and/or attenuators of minimum value 
of 6 dB shall be inserted. 
 
 
4.4.2 Test Block Diagram: 
 
 
 
 
 
EUT 
 
Combining 
Network 
Signal Generator 
 
EMI Receiver 