ON CALL (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 14

Read JBL ON CALL (serv.man4) EMC - CB Certificate online

 
 
 
 
EMC Report for Harman Model JBL On Call 5310 
File: 3129326LAX-009 
Page 14 of 26 
 
100 VAC 60 Hz: 
Neutral Conductor Measurement: 
 
 
Frequency 
 
Level  (AV) 
 
Limit (AV) 
 
Level (QP) 
 
Limit (QP) 
 
Margin 
 
MHZ 
 
(dBµV) 
 
(dBµV) 
 
(dBµV) 
 
(dBµV) 
 
dB 
0.152 
20.3 
55.9 
48.0 
65.9 
-17.9 
0.196 
27.1 
54.0 
43.6 
64.0 
-20.4 
0.373 
24.4 
48.5 
38.2 
58.5 
-20.3 
1.320 
20.3 
46.0 
35.8 
56.0 
-20.2 
5.800 
31.3 
50.0 
43.8 
60.0 
-16.2 
7.800 
24.4 
50.0 
35.1 
60.0 
-24.9 
 
Line Conductor Measurement:  
 
 
Frequency 
 
Level  (AV) 
 
Limit (AV) 
 
Level (QP) 
 
Limit (QP) 
 
Margin 
 
MHZ 
 
(dBµV) 
 
(dBµV) 
 
(dBµV) 
 
(dBµV) 
 
dB 
0.152 
19.7 
55.9 
47.5 
65.9 
-18.4 
0.196 
26.8 
54.0 
42.8 
64.0 
-21.2 
0.373 
28.6 
48.5 
42.3 
58.5 
-16.2 
1.320 
22.5 
46.0 
39.4 
56.0 
-16.6 
5.800 
34.7 
50.0 
46.8 
60.0 
-13.2 
7.800 
28.7 
50.0 
39.7 
60.0 
-20.3 
 
Note :    a)   All other measurements  were more than 20 dBs below the limit lines.   
 
 b)   A complete scan from 0.15 - 30 MHz was made. 
 c)   Analyzer setting:   RBW  
9 kHz, VBW  
9 kHz 
 
       Detector mode:  
Quasi peak and average 
 
Scans on the next page(s) show conducted emissions measurements 
 
TEST RESULT: 
EUT PASSED Conducted emissions test with 13.2 dB margin at 5.800 MHz. 
 
 
 
 
Page of 26