Read JBL ON CALL (serv.man4) EMC - CB Certificate online
EMC Report for Harman Model JBL On Call 5310
File: 3129326LAX-009
Page 14 of 26
100 VAC 60 Hz:
Neutral Conductor Measurement:
Neutral Conductor Measurement:
Frequency
Level (AV)
Limit (AV)
Level (QP)
Limit (QP)
Margin
MHZ
(dBµV)
(dBµV)
(dBµV)
(dBµV)
dB
0.152
20.3
55.9
48.0
65.9
-17.9
0.196
27.1
54.0
43.6
64.0
-20.4
0.373
24.4
48.5
38.2
58.5
-20.3
1.320
20.3
46.0
35.8
56.0
-20.2
5.800
31.3
50.0
43.8
60.0
-16.2
7.800
24.4
50.0
35.1
60.0
-24.9
Line Conductor Measurement:
Frequency
Level (AV)
Limit (AV)
Level (QP)
Limit (QP)
Margin
MHZ
(dBµV)
(dBµV)
(dBµV)
(dBµV)
dB
0.152
19.7
55.9
47.5
65.9
-18.4
0.196
26.8
54.0
42.8
64.0
-21.2
0.373
28.6
48.5
42.3
58.5
-16.2
1.320
22.5
46.0
39.4
56.0
-16.6
5.800
34.7
50.0
46.8
60.0
-13.2
7.800
28.7
50.0
39.7
60.0
-20.3
Note : a) All other measurements were more than 20 dBs below the limit lines.
b) A complete scan from 0.15 - 30 MHz was made.
c) Analyzer setting: RBW
c) Analyzer setting: RBW
≥
9 kHz, VBW
≥
9 kHz
Detector mode:
Quasi peak and average
Scans on the next page(s) show conducted emissions measurements
TEST RESULT:
EUT PASSED Conducted emissions test with 13.2 dB margin at 5.800 MHz.
Click on the first or last page to see other ON CALL (serv.man4) service manuals if exist.