Report Ref. No. 086-2101101501-000
TRF No.: IEC/EN60950_1c
1.6.3
Voltage limit of hand-held equipment
This appliance is not a
handheld equipment.
N/A
1.6.4
Neutral conductor
Class III equipment.
N/A
1.7
Marking and instructions
P
1.7.1
Power rating
See below
P
Rated voltage(s) or voltage range(s) (V)  ............. : 13VDC
P
Symbol for nature of supply, for d.c. only ............. :
IEC 60417, symbol No.
5031, is used.
P
Rated frequency or rated frequency range (Hz)  .. :
DC supplied.
N/A
Rated current (mA or A)  ..................................... : 2.5A
P
Manufacturer’s name or trade-mark or
identification mark  .............................................. :
P
Model identification or type reference  ................. : JBL OnBeat
P
Symbol for Class II equipment only  .................... : Class III equipment.
N/A
Other markings and symbols  .............................. : Additional symbols or
markings that do not give
rise to misunderstand.
P
1.7.2
Safety instructions and marking
Safety instructions in
English and German.
Other languages will be
provided separately when
submitted for national
approval.
P
1.7.2.1
General
Considered.
P
1.7.2.2
Disconnect devices
Class III equipment.
P
1.7.2.3
Overcurrent protective device
Class III equipment.
N/A
1.7.2.4
IT power distribution systems
Class III equipment.
N/A
1.7.2.5
Operator access with a tool
Class III equipment.
P
1.7.2.6
Ozone
N/A
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
N/A
1.7.4
Supply voltage adjustment  ................................ :  No voltage/frequency
setting.
N/A
Methods and means of adjustment; reference to
installation instructions  ...................................... :
N/A
1.7.5
Power outlets on the equipment  ......................... :  No outlet provided.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference)  ........................ :
No fuse
N/A
1.7.7
Wiring terminals
N/A
1.7.7.1
Protective earthing and bonding terminals  ......... :  Class III equipment.
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
Class III equipment.
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
Class III equipment.
N/A
Page of 82