Report Ref. No. 086-2101101501-000
TRF No.: IEC/EN60950_1c
4.5.5
Resistance to abnormal heat  ............................. :  No thermoplastic parts
carrying hazardous
voltages.
N/A
4.6
Openings in enclosures
N/A
4.6.1
Top and side openings
No openings, no hazard
N/A
Dimensions (mm)  .............................................. :
4.6.2
Bottoms of fire enclosures
No fire enclosure
N/A
Construction of the bottomm, dimensions (mm)  . :
4.6.3
Doors or covers in fire enclosures
N/A
4.6.4
Openings in transportable equipment
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions (mm)  .............................................. :
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A
Conditioning temperature ( C), time (weeks) ...... :
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame 
Method 1 is used.
P
Method 1, selection and application of components
wiring and materials
Equipment is class III
equipment, powered by
separately certified LPS
adaptor
P
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
Refer to  cl. 4.7.2.2
N/A
4.7.2.2
Parts not requiring a fire enclosure
Fire enclosure is not
required, class III equipment
supplied by Limited Power
Source. Components
mounted on material of min.
V-1 material.
P
4.7.3
Materials
P
4.7.3.1
General
Components and materials
have adequate flammability
classification. (see
appended table 1.5.1)
P
4.7.3.2
Materials for fire enclosures
Fire enclosure is not
required, class III equipment
supplied by Limited Power
Source. Components
mounted on material of min.
V-1 material.
N/A
Page of 82