Read JBL ON BEAT MINI EMC - CB Certificate online
Korea Testing Certification
Page 8 of 16
Report No.: W13-950-006
(EN 60950-1:2006+A11:2009+A1:2010+A12:2011)
IEC60950_1B - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
2.7.1
Replace the subclause as follows:
Basic requirements
To protect against excessive current, short-
circuits and earth faults in PRIMARY CIRCUITS,
protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a), b)
and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as parts of
the equipment;
b) for components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided
by protective devices in the building installation;
Basic requirements
To protect against excessive current, short-
circuits and earth faults in PRIMARY CIRCUITS,
protective devices shall be included either as
integral parts of the equipment or as parts of the
building installation, subject to the following, a), b)
and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 5.3 shall be included as parts of
the equipment;
b) for components in series with the mains input
to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch, short-
circuit and earth fault protection may be provided
by protective devices in the building installation;
N/A
c) it is permitted for PLUGGABLE EQUIPMENT
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent
and short-circuit protection in the building
installation, provided that the means of protection,
e.g. fuses or circuit breakers, is fully specified in
the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be regarded
as providing protection in accordance with the
rating of the wall socket outlet.
TYPE B or PERMANENTLY CONNECTED
EQUIPMENT, to rely on dedicated overcurrent
and short-circuit protection in the building
installation, provided that the means of protection,
e.g. fuses or circuit breakers, is fully specified in
the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for PLUGGABLE EQUIPMENT
TYPE A the building installation shall be regarded
as providing protection in accordance with the
rating of the wall socket outlet.
N/A
2.7.2
This subclause has been declared ‘void’.
N/A
3.2.3
Delete the NOTE in Table 3A, and delete also in
this table the conduit sizes in parentheses.
this table the conduit sizes in parentheses.
N/A
3.2.5.1
Replace
“60245 IEC 53” by “H05 RR-F”;
“60227 IEC 52” by “H03 VV-F or
H03
VVH2-F”;
“60227 IEC 53” by “H05 VV-F or
H05
VVH2-F2”.
In Table 3B, replace the first four lines by the
following:
Up to and including 6 |
following:
Up to and including 6 |
0,75
a)
|
Over 6 up to and including 10| (0,75)
b)
1,0 |
Over 10 up to and including 16| (1,0)
c)
1,5 |
In the conditions applicable to Table 3B delete
the words “in some countries” in condition
the words “in some countries” in condition
a)
.
In NOTE 1, applicable to Table 3B, delete the
second sentence.
second sentence.
N/A