Read JBL ON BEAT MINI (serv.man2) EMC - CB Certificate online
Page 8 of 99 Report No.: NTEK-2012DC1231016E
NOTE:
(1)” N/A” denotes test is not applicable in this Test Report
(2)
The power consumption of EUT is less than 75W and no Limits apply.
(3)
Voltage dip: 100% reduction – Performance Criteria B
Voltage dip: 30% reduction – Performance Criteria C
Voltage Interruption: 100% Interruption – Performance Criteria C
(4) For client’s request and manual description, the test will not be executed.
1.1 TEST FACILITY
Shenzhen NTEK Testing Technology Co., Ltd
Shenzhen NTEK Testing Technology Co., Ltd
Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District,
Shenzhen P.R. China
.
FCC Registration Number:238937; IC Registration Number:9270A-1
CNAS Registration Number:L5516
1.2 MEASUREMENT UNCERTAINTY
The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
approximately 95 %.
standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
approximately 95 %.
A. Conducted Measurement :
Test Site Method
Measurement Frequency Range
U,(dB)
NOTE
NTEKC01 ANSI
150 KHz ~ 30MHz
3.2
B. Radiated Measurement :
Test Site Method
Measurement Frequency Range
U,(dB)
NOTE
NTEKA01 ANSI
30MHz ~ 1000MHz
4.7
1GHz
~6GHz
5.0
C. Disturbance Power Measurement :
Test Site Method
Measurement Frequency Range
U,(dB)
NOTE
NTEKC01 ANSI
30 KHz ~ 300MHz
3.5