Read JBL ON BEAT AIR (serv.man3) EMC - CB Certificate online
ATTACHMENT
National Differences
Page 109 of 116
Report No.: 11023927 001
National Differences
Clause
Requirement + Test
Result – Remark
Verdict
0,05 – 0,34
0.35 – 0,49
0,50 – 0,74
0,75 – 2,49
0.35 – 0,49
0,50 – 0,74
0,75 – 2,49
2,50 – 5,00
4,0
6,0
8,0
6,0
8,0
10,0
4 times of the
diameter of
conductor
1)
1)
in compliance with IEC 60317-43.
The tension to be applied to the wire during
winding on the mandrel is calculated from the
wire diameter to be equivalent to 118 Mpa ± 10 %
(118 N/mm
winding on the mandrel is calculated from the
wire diameter to be equivalent to 118 Mpa ± 10 %
(118 N/mm
2
± 10 %).
U.2.3
Replace the first paragraph of this Sub-Clause
by:
by:
Test 9 of IEC 60851-6:1996, followed by the
electric strength test of 5.2.2 of this standard
except applying the test voltage between the
wire and the mandrel. A test voltage shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be
as follows:
electric strength test of 5.2.2 of this standard
except applying the test voltage between the
wire and the mandrel. A test voltage shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be
as follows:
-
for BASIC INSULATION or
SUPPLEMENTARY INSULATION, 1500 V,
or;
SUPPLEMENTARY INSULATION, 1500 V,
or;
- for REINFORCED INSULATION, 3000 V.
Replaced.
P
U.2.4
Replace the third paragraph of this Sub-Clause,
which is describing the test voltage, by:
which is describing the test voltage, by:
The test voltage shall not be less than the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be
as follows:
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be
as follows:
-
for BASIC INSULATION or
SUPPLEMENTARY INSULATION, 1500 V,
or;
SUPPLEMENTARY INSULATION, 1500 V,
or;
-
for REINFORCED INSULATION, 3000 V.
It is applied between the shot and the conductor.
Replaced.
P
U.3.1
Replace the text of this Sub-Clause by:
The test voltage for ROUTINE TESTING shall be
the appropriate voltage in table 5B (see 5.2.2) of
this standard. However, the minimum values
shall be as follows:
the appropriate voltage in table 5B (see 5.2.2) of
this standard. However, the minimum values
shall be as follows:
-
for BASIC INSULATION or
SUPPLEMENTARY INSULATION, 1500 V
r.m.s. or 2100 V peak, or;
SUPPLEMENTARY INSULATION, 1500 V
r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V
r.m.s. or 4200 V peak.
Replaced.
P