Read JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate online
Report No. U1011006-610
Page 9 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.7.12
Removable parts
No removable part provided
except for the remote control.
except for the remote control.
N/A
1.7.13
Replaceable batteries .......................................... :
No replaceable batteries
provided.
provided.
N/A
Language(s) ........................................................ :
Same as above.
1.7.14
Equipment for restricted access locations ............ :
No restricted access location.
N/A
2
PROTECTION FROM HAZARDS
The equipment is power supplied from the external power adaptor which is complied
with the requirement of Limited Power Source. No risk of electrical shock or energy
hazards.
with the requirement of Limited Power Source. No risk of electrical shock or energy
hazards.
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
See below.
P
2.1.1.1
Access to energized parts
No access with test finger and
test pin to any parts with only
basic insulation to ELV or
hazardous voltage. Any
hazardous parts accessible are
unlikely.
test pin to any parts with only
basic insulation to ELV or
hazardous voltage. Any
hazardous parts accessible are
unlikely.
P
Test by inspection .................................................. : Same as above.
P
Test with test finger (Figure 2A) ............................ : Same as above.
P
Test with test pin (Figure 2B) ................................ : Same as above.
P
Test with test probe (Figure 2C) ............................ : No TNV circuits in this
equipment.
N/A
2.1.1.2
Battery compartments
No battery compartments and
TNV circuits.
TNV circuits.
N/A
2.1.1.3
Access to ELV wiring
No ELV wiring in operator
accessible area.
accessible area.
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
Same as above.
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage wiring in
operator accessible area.
operator accessible area.
N/A
2.1.1.5
Energy hazards ..................................................... : No energy hazard in operator
access area.
P
2.1.1.6
Manual controls
No conductive shaft of
operating knob and handle.
operating knob and handle.
N/A
2.1.1.7
Discharge of capacitors in equipment
Class III equipment.
N/A
Measured voltage (V); time-constant (s) ................ : Same as above.
2.1.1.8
Energy hazards – d.c. mains supply
Class III equipment..
N/A
a) Capacitor connected to the d.c. mains supply .. : Same as above.
N/A
Same as above.
N/A
2.1.1.9
Audio amplifiers ..................................................... : See sub-clause 2.1.1.1
P