Read JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate online
Report No. U1011006-610
Page 8 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.7.2.3
Overcurrent protective device
This equipment is not
permanently connected
equipment or pluggable
equipment.
permanently connected
equipment or pluggable
equipment.
N/A
1.7.2.4
IT power distribution systems
Class III equipment.
N/A
1.7.2.5
Operator access with a tool
No tool is required to gain
access to operator access
area.
access to operator access
area.
N/A
1.7.2.6
Ozone
No ozone produces within this
equipment.
equipment.
N/A
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment ................................... :
No voltage adjustment device
provided.
provided.
N/A
Methods and means of adjustment; reference to
installation instructions ......................................... :
installation instructions ......................................... :
Same as above.
N/A
1.7.5
Power outlets on the equipment ........................... :
No outlet provided.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :
characteristics, cross-reference) .......................... :
No such component within the
equipment.
equipment.
N/A
1.7.7
Wiring terminals
Class III equipment.
N/A
1.7.7.1
Protective earthing and bonding terminals ........... :
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
See below.
P
1.7.8.1
Identification, location and marking ...................... :
The marking and indication is
located that indication of
function clearly.
located that indication of
function clearly.
P
1.7.8.2
Colours ................................................................ :
No safety relevant controls or
indicators.
indicators.
N/A
1.7.8.3
Symbols according to IEC 60417 ......................... :
No such symbol provided.
N/A
1.7.8.4
Markings using figures ....................................... :
No indicators for different
positions.
positions.
N/A
1.7.9
Isolation of multiple power sources ..................... :
Class III equipment.
N/A
1.7.10
Thermostats and other regulating devices .......... :
No such device provided.
N/A
1.7.11
Durability
The labels were subjected to
the permanence of marking
test. The labels were rubbed
with cloth soaked with water for
15 s and then again for 15 s
with the cloth soaked with
petroleum spirit.
After this test there was no
damage to the labels. The
marking on the labels did not
fade. There was no curling or
lifting of the label's edges.
the permanence of marking
test. The labels were rubbed
with cloth soaked with water for
15 s and then again for 15 s
with the cloth soaked with
petroleum spirit.
After this test there was no
damage to the labels. The
marking on the labels did not
fade. There was no curling or
lifting of the label's edges.
P