ON AIR WIRELESS (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 55

Read JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate online

ATTACHMENT 
 
Report No: U1011006-610 
National Differences 
 
Page 10 of 12 
 
National Differences 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
US National Differences 
3.2.5  
Power supply cords are required to be no longer 
than 4.5 m in length and minimum length shall be 
1.5 m. Flexible power supply cords are required to 
be compatible with Article 400 of the NEC.  
Class III equipment. Not directly 
connected to the mains. 
N/A 
3.2.9  
Permanently connected equipment must have a 
suitable wiring compartment and wire bending 
space.  
Not such equipment. 
N/A 
3.3.3  
Wire binding screws are not permitted to attach 
conductors larger than 10 AWG (5.3 mm2).  
No such consideration. 
N/A 
3.3.4  
Terminals for permanent wiring, including 
protective earthing terminals, must be suitable for 
U.S wire gauge sizes, rated 125 percent of the 
equipment rating, and be specially marked when 
specified (1.7.7).  
No such consideration. 
N/A 
3.4.2  
Motor control devices are required for cord-
connected equipment with a motor if the 
equipment is rated more than 12 A, or if the motor 
has a nominal voltage rating greater than 120 V, 
or is rated more than 1/3 hp (locked rotor current 
over 43 A).  
No such consideration. 
N/A 
3.4.8  
Vertically-mounted disconnect switches and 
circuit breakers are required to have the "on" 
position indicated by the handle in the up position.  
No such consideration. 
N/A 
3.4.11  
For computer room applications, equipment with 
battery systems capable of supplying 750 VA for 
five minutes are required to have a battery 
disconnect means that may be connected to the 
computer room remote power-off circuit.  
Not such equipment. 
N/A 
4.3.12  
The maximum quantity of flammable liquid stored 
in equipment is required to comply with NFPA 30.  
No such consideration. 
N/A 
4.3.13.5  
Equipment with lasers is required to meet the 
Code of Federal Regulations 21 CFR 1040.  
No laser. 
N/A 
4.7  
For computer room applications, automated 
information storage systems with combustible 
media greater than 0.76 m3 (27 cu ft) are 
required to have a provision for connection of 
either automatic sprinklers or a gaseous agent 
extinguishing system with an extended discharge.  
No such consideration. 
N/A 
4.7.3.1  
For computer room applications, enclosures with 
combustible material measuring greater than 0.9 
m2  (10 sq ft) or a single dimension greater than 
1.8 m  (6 ft) are required to have a flame spread 
rating of 50 or less.  For other applications, 
enclosures with the same dimensions require a 
flame spread rating of 200 or less.   
No such consideration. 
N/A 
Annex H  
Equipment that produces ionizing radiation must 
comply with Federal Regulations, 21 CFR 1020  
No CRT. 
N/A 
Page of 62
Display