ON AIR WIRELESS (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 54

Read JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate online

ATTACHMENT 
 
Report No: U1011006-610 
National Differences 
 
Page 9 of 12 
 
National Differences 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
US National Differences 
 
US National Differences 
SPECIAL NATIONAL CONDITIONS BASED ON FEDERAL REGULATIONS 
1.1.1  
All equipment is to be designed to allow 
installation in accordance with the National 
Electrical Code (NEC), ANSI/NFPA 70, and when 
applicable, the National Electrical Safety Code, 
IEEE C2.  Also, unless marked or otherwise 
identified, installation is allowed per the Standard 
for the Protection of Electronic Computer/Data-
Processing Equipment, ANSI/NFPA 75.  
EUT in compliance with 
requirements of IEC 60950-1. 
Overall acceptance shall be 
evaluated during national 
approval. 
N/A 
1.4.14  
For Pluggable Equipment Type A, the protection 
in the installation is assumed to be 20A.  
Class III equipment. Not directly 
connected to the mains. 
N/A 
1.5.5  
For lengths exceeding 3.05 m, external 
interconnecting flexible cord and cable 
assemblies are required to be a suitable cable 
type specified in the NEC. For lengths 3.05 m or 
less, external interconnecting flexible cord and 
cable assemblies that are not types specified in 
the NEC are required to have special construction 
features and identification markings.  
No such consideration. 
N/A 
1.7.1  
Equipment for use on a.c. mains supply systems 
with a neutral and more than one phase 
conductor (e.g. 120/240 V, 3-wire) require a 
special marking format for electrical ratings.  
Class III equipment. Not directly 
connected to the mains. 
N/A 
2.5  
Where a fuse is used to provide Class 2, Limited 
Power Source, or TNV current limiting, it shall not 
be operator-accessible unless it is not 
interchangeable.  
No such fuse. 
N/A 
2.7.1  
Suitable NEC branch circuit protection rated at 
the maximum circuit rating is required for all 
standard supply outlets and receptacles (such as 
supplied in power distribution units) if the supply 
branch circuit protection is not suitable.  Power 
distribution transformers distributing power at 100 
volts or more, and rated 10 kVA or more, require 
special transformer overcurrent protection.  
Class III equipment. Not directly 
connected to the mains. 
N/A 
3.2  
Wiring methods (terminals, leads, etc.) used for 
the connection of the equipment to the mains 
shall be in accordance with the NEC.  
Class III equipment. Not directly 
connected to the mains. 
N/A 
3.2.1  
Power supply cords are required to have 
attachment plugs rated not less than 125 percent 
of the rated current of the equipment.  
Same as above. 
N/A 
3.2.1.2  
Equipment connected to a centralized d.c. power 
system, and having one pole of the DC mains 
input terminal connected to the main protective 
earthing terminal in the equipment, is required to 
comply with special earthing, wiring, marking and 
installation instruction requirements.  
Same as above. 
N/A 
3.2.3  
Permanent connection of equipment to the mains 
supply by a power supply cord is not permitted, 
except for certain equipment, such as ATMs.  
Not such equipment. 
N/A 