Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
16.3b 
(16.4b) 
 
Delete “Subclause 3.1 of IEC Publication 60227-2: Part 2: 
Test Methods“ and insert “Subclause 9.1 of SS 236“: 
9.1 Flexing test (except for tinsel cords, twisted twin and 
single core cords). The test shall be carried out  by means of 
the apparatus shown in Figure 5. This apparatus has a 
carrier C supporting two pulleys A and B arranged so that 
the cord is horizontal between the pulleys. The carrier 
moves backward and forward over a distance of 1 m at an 
approximately constant speed of 0.33 m/s.                
A sample of flexible cord about 5 m long shall be stretched 
over the pulleys as shown in the figure, each end being 
loaded with a weight. The weight and the diameter of the 
pulleys A and B shall be given in Table 1. 
Screene cords in accordance with Table 7 shall be tested 
before application of the screen and outer sheath.                 
The pulleys shall have a semi-circular shaped groove for 
circular cords and a flat groove for parallel twin cords. The 
restraining clamps D shall be fixed so that the pull is 
always applied by the weight from which the carrier is 
moving away. The carrier shall make 30 000 backward and 
forward movements (60 000 single strokes). Each 
conductor of the sample shall be loaded with the current 
specified in Table 2.                                
For twin cords and for light PVC-sheated 3-core cords, the 
voltage between the conductors shall be approximately 230 
V a.c. For all other cords having three or more cores a 
three-phase a.c. voltage of about 400 V shall be applied to 
three conductors, any additional conductors being 
connected to the neutral.                                
During the test no open-circuit in any core or short-circuit 
between cores shall occur.                                                  
After the test, any sheath on cords having three or more 
cores shall be removed. The cord, or the laid up cores, 
shall then withstand the voltage test specified in Subclause 
8.2 or 8.3 as appropriate, but with a test voltage not 
exceeding 2000 V. 