Read JBL ESC Xcite EMC - CB Certificate online
page 32 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
National differences for Singapore
(These differences are taken from IEC 60065:1993 and adopted to IEC 60065:1998)
IEC 60065:1998
Clauses: 4, 7,9,10,16.
SG 03
Throughout the standard, whenever the words "white pine board" appear, insert
the words "or plywood board" to it.
the words "or plywood board" to it.
Noted
SS143 Amendment No. 1 and No. 2
4.1.3
(4.1.3)*
Delete "45 % to 75 %" and insert 65 ± 5 %.
75% maximum in
IEC 60065: 1998
IEC 60065: 1998
P
7.1
(7.1)
Resistance to heat without external forces.
Adopt the temperature specified for the tropical conditions.
P
8.6
(9.3.4)
Delete the note " A Quality Assessment System for
capacitors complying with Subclause 14.2 is under
consideration in the IEC".
capacitors complying with Subclause 14.2 is under
consideration in the IEC".
This is not in
IEC 60065:1998.
IEC 60065:1998.
Noted
10.2
(10.2)
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
conditions.
120 h at a relative
humidity of 93%.
humidity of 93%.
P
16
(16)
External flexible cords
Delete "IEC Publication 60227: Polyvinyl Chloride Insulated
Cables of Rated Voltages up to and Including 450/750 V
and IEC publication 60245: Rubber insulated Cables of
rated up to and including 450/750 V " and insert "Singapore
Standard 236: Flexible Cords", whenever they appear in
this clause.
Cables of Rated Voltages up to and Including 450/750 V
and IEC publication 60245: Rubber insulated Cables of
rated up to and including 450/750 V " and insert "Singapore
Standard 236: Flexible Cords", whenever they appear in
this clause.
Delete "CEE Publication 13, CEE Publication 2 and IEC
Publication 60173: Colours of the Cores of Flexible Cables
and Cords" whenever they appear in this clause.
Publication 60173: Colours of the Cores of Flexible Cables
and Cords" whenever they appear in this clause.
Noted
16.2
(16.2)
Delete the notes in small print and insert "A nominal cross-
sectional area of 0.75 mm² will satisfy this requirement".
sectional area of 0.75 mm² will satisfy this requirement".
This is not in
IEC 60065:1998.
IEC 60065:1998.
Noted
* in parenthesis: clauses acc. to IEC 60065:1993
Click on the first or last page to see other ESC Xcite service manuals if exist.