Rev. No. 1.2 
5.9 
Electrical fast transients / Burst 
For test instruments and accessories used see section 6 Part I 4
5.9.1  Description of the test location 
 
Test location: 
Shielded Room S3 
 
5.9.2  Photo documentation of the test set-up 
 
 
 
5.9.3 Test 
specification 
 
Coupling network: 1 
kV 
 
Burst frequency: 5.0 
kHz 
 
Coupling duration: 
≥ 60 sec. 
 
Polarity: 
- positive 
- negative 
 