ES 250P (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 17

Read JBL ES 250P (serv.man3) EMC - CB Certificate online

 
mikes-testingpartners gmbh
 File 
No. 
F30995-00-00HM
, page 
16 of 22 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.2 
5.7.3 Test 
specification 
 
Contact discharge voltage: 
2 kV 
4 kV 
 
Air discharge voltage: 
2 kV 
4 kV 
8 kV 
 
Discharge impedance: 
330 
Ω / 150 pF 
 
Discharge factor: 
≥ 1 sec. 
 
Number of discharges: 
≥ 10 
 
Type of discharge: 
Direct discharge: 
- Contact discharge 
 
- Air discharge 
 
Indirect discharge: 
- Air discharge 
 
Polarity: 
- positive 
- negative 
 
Discharge location: 
- all external locations accessible by hand 
- vertical coupling plate (VCP) 
- horizontal plate (HCP) 
- see photo documentation of the test set-up 
 
 
5.7.4 Test 
result 
 
The requirements are 
FULFILLED. 
Performance Criterion:
 B 
 
Remarks: 
During electrostatic discharge the sine wave disappears and then reappears by itself. 
 
 
 
 
 
 
 
 
 
Page of 23
Display

Click on the first or last page to see other ES 250P (serv.man3) service manuals if exist.