ES 250P (serv.man2) - JBL Audio Service Manual (repair manual). Page 13

Read JBL ES 250P (serv.man2) Service Manual online

Yes/No
Hi/Lo Line
Nom.
Unit
Notes
Turn-off Transient
0.5
V-peak
0.8V
@ Speaker Output
AC Line cycled from ON to OFF
Efficiency
Efficiency
65
%
60
Test conducted at rated power 
250W
Nominal Line voltage 
Efficiency at 1/8 of rated power
48
%
45
Test conducted at 31.25 WRMS Nominal Line voltage-Rated impedance 4 Ohms
Off state input power
10
Watts
12
Nominal Line voltage  RED LED
Stand-by Input Power
18
Watts
18
@ nom. line voltage
Maximum allowable  input power under nominal  
Input voltage and frequency, HOT or COLD 
operation. LED GREEN no signal applied
Power Cons. @ rated power
406
Watts
416
@ nom. line voltage
250 Watts @ 4 Ohms nominal line voltage
Protections
Short Circuit Protection 
YES
functional  Direct short at output
Amplifier should resume operation after short 
circuit condition removal 
Thermal Protection 
YES
functional
@1/8 max unclipped Power at 
1.06 times the input voltage
Temperature rise in accessible metal parts 
should not exceed 35K rise for domestic version 
requirements sheet).
DC Offset Protection
YES
-
DC present at Speaker Out leads
Design must insure no Offset at the speaker 
output  under any operating condition including 
abnormal operation
Line Fuse Rating
USA-Domestic 
3.15
Amps
3.15
Type-T or Slo Blo-250 V
EU
2
Amps
2
Type-T or Slo Blo-250 V, Low 
Breaking capacity
Other Parameters/Notes:
1. Limiter circuit response must be clean sounding with no apparent pops, noises, or pumping.
2. Volume control should be at the input buffer stage  in order to lessen the possibility of clipping the input section with highly dynamic audio material.
3. ALL SPECS SHOULD BE MEASURED AT NOMINAL LINE VOLTAGE. 
 
 ES250P 
 
 
 
 
 
 
 
 
 
 
 
   
      
 
 
 
JBL ES 250P
Service Manual
Page 13 of 30
Page of 30
Display