Read JBL ES 150PW (serv.man5) EMC - CB Certificate online
Page 24 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by position of
the functional switch (W)……………………… ……..:
the functional switch (W)……………………… ……..:
0W/0.2W
—
Cond.
Un (V)
Hz
In (mA)
Pn (W)
V out
Pout (W)
Operating Condition
1 253 50 386 55 11.5 37
2 198 50 342 45 9.8 27
1/8 of max non-clipping output
power (pink noise)
power (pink noise)
Transformer model TT0900901830-E
Loudspeaker impedance (Ω) ..................................:
Measured DC resistance: 3.54Ω
—
Several loudspeaker systems
—
Marking of loudspeaker terminals
—
—
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
No 1
No ___
No ___
Primary wiring insulation
24
-
-
60 (50)
Transformer steel washer
35
-
-
-
PCB 37
-
-
85
(75)
Heat sink (supported by PCB)
37
-
-
85 (75)
33
-
-
60 (50)
Rear panel, metal (likely to be touched)
outside of heat sink
outside of heat sink
26 - -
40
(30)
Knobs (non metallic)
13
-
-
50 (40)
Top enclosure, wood
6
-
-
60 (50)
TR1 windings (measured with thermocouple)
24
-
-
75 (65)
PCB (Standby SMPS))
22
-
-
85 (75)
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ..............................
Ambient temperature t2 (
o
C) ..............................
23
26
— — —
—
Temperature rise dT of winding:
dT = (R
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit
maxK)
Insulation class
Transformer model TT0900901830-E
Primary winding
5.279
6.057
35
85 (75)
E
Secondary winding (red-red)
0.5564
0.6332
33
85 (75)
E
Secondary winding (blue-blue)
1.4914
1.7005
33
85 (75)
E
The limit values in parenthesis are the limit values for tropical climate.
Click on the first or last page to see other ES 150PW (serv.man5) service manuals if exist.