Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
 P 
14.5.1.1 
a) Thermal cut-outs separately approved  
 
N/A 
 
b) Thermal cut-outs tested as part of the submission   
N/A 
14.5.1.2 
a) Thermal links separately approved  
 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
 P 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ...: 
T2.0AL/250V (ES150P/230) 
T2.0AL/250V (ES150PW/230) 
On standby PCB:  
FUSE T250mA  L/250V 
14.5.2.3 
Not possible to connect fuses in parallel ................: 
No 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  .........: 
Tools are required 
14.5.3 
PTC thermistors comply with IEC 60730-1  
 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked  
 P 
14.6 
Switches  
(see appended table) 
14.6.1 a) 
Separate testing to IEC 61058 including: 
- 10 000 operations 
- Normal pollution suitability 
- Resistance to heat and fire level 3 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
Mains switch: 48..4A (measured 
peak surge current) 
Mains relay K1: 40.6 A 
(measured peak surge current) 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage 
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 N/A 
 
Switch controlling > 0.2A with open contact  voltage  
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 N/A 
 
Switch controlling < 0.2A with open contact  voltage 
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 N/A 
Page of 84