Read JBL ES 150PW (serv.man4) EMC - CB Certificate online
ELECTRONICS TESTING CENTER(ETC), TAIWAN
File No. : 08-07-RBF-038-01
EMC TESTING DEPARTMENT II
Page: 8 / 42
3 SUMMARY OF TEST RESULTS
3.1 Emissions:
3.1.1 Conducted Emissions
[X] – PASS (AV In -Neutral)
Minimum EMI QP Margin to the limit:
Minimum EMI QP Margin to the limit:
-13.6 dB at
1.843 MHz
[X] – PASS (AV In -Line)
Minimum EMI QP Margin to the limit:
Minimum EMI QP Margin to the limit:
-13.9 dB at
1.851 MHz
[X] – PASS (Link In -Neutral)
Minimum EMI QP Margin to the limit:
Minimum EMI QP Margin to the limit:
-23.6 dB at
1.476 MHz
[X] – PASS (Link In -Line)
Minimum EMI QP Margin to the limit:
Minimum EMI QP Margin to the limit:
-19.4 dB at
1.476 MHz
3.1.2 Radiated Emissions
[X] – PASS (AV In -HOR)
Minimum EMI Margin to the limit:
Minimum EMI Margin to the limit:
-9.3 dB at
157.370 MHz
[X] – PASS (AV In -VER)
Minimum EMI Margin to the limit:
Minimum EMI Margin to the limit:
-11.0 dB at
184.470 MHz
[X] – PASS (Link In -HOR)
Minimum EMI Margin to the limit:
Minimum EMI Margin to the limit:
-8.8 dB at
171.730 MHz
[X] – PASS (Link In -VER)
Minimum EMI Margin to the limit:
Minimum EMI Margin to the limit:
-10.4 dB at
159.540 MHz
3.1.3 Harmonics Current Emissions
[X] – PASS
The harmonics current values were under the limits of the class A equipment of the
EN 61000-3-2.
The harmonics current values were under the limits of the class A equipment of the
EN 61000-3-2.
3.1.4 Voltage Fluctuations and Flicker
[X] – PASS
The voltage fluctuations and flicker values were under the limits of the
EN 61000-3-3 requirements.
The voltage fluctuations and flicker values were under the limits of the
EN 61000-3-3 requirements.
Click on the first or last page to see other ES 150PW (serv.man4) service manuals if exist.