Read JBL ES 150PW (serv.man3) EMC - CB Certificate online
Report No:W-N-1002010-CY-01-1
Telecom Technology Center
4
3. Test Mode & EUT Components Description
To investigate the maximum EMI emission characteristics generates from EUT, the
test system was pre-scanning tested base on the consideration of following EUT
operation mode or test configuration mode which possible have effect on EMI
emission level. Each of these EUT operation mode(s) or test configuration mode(s)
mentioned above was evaluated respectively.
Data of test
2010/02/25
Temperature
23.3 ℃
Location
DTV Shield Room
Humidity
39 %RH
Data of test
2010/02/25
Temperature
15.1 ℃
Location
Fully Anechoic Chamber Humidity
62 %RH
Data of test
2010/02/25
Temperature
21.4 ℃
Location
EFT Room
Humidity
44 %RH
Data of test
2010/02/25
Temperature
22.1 ℃
Location
ESD Room
Humidity
50 %RH
Test Mode
Monitor
Sound
Sound play mode
Speaker PASS
Click on the first or last page to see other ES 150PW (serv.man3) service manuals if exist.