Read JBL ES 150PW (serv.man3) EMC - CB Certificate online
Report No:W-N-1002010-CY-01-1
Telecom Technology Center
2
2. SUMMARY OF TEST RESULTS
2.1 Test Result
2.1 Test Result
The EUT has been tested according to the following specifications:
IMMUNITY(EN 55020: 2007)
Standard
Test Type
Result
Remarks
Input immunity
N/A
The immunity test at antenna
input terminal of EUT.
The performance criteria is A
input terminal of EUT.
The performance criteria is A
Immunity to Induced voltages PASS
The immunity test at Audio
and mains terminal of EUT by
CDN.
The performance criteria is A
and mains terminal of EUT by
CDN.
The performance criteria is A
Immunity to RF voltage at
antenna terminal
antenna terminal
N/A
The immunity test at antenna
input terminal of EUT by
CDN.
The performance criteria is A
input terminal of EUT by
CDN.
The performance criteria is A
Immunity from radiated
fields
fields
PASS
The immunity test at enclosure
of EUT by open strip line.
The performance criteria is A
of EUT by open strip line.
The performance criteria is A
EN 55020:2007
Screening effectiveness
N/A
The screening effectiveness is
≧
≧
50dB
EN 55020:2007
IEC 61000-4-2
IEC 61000-4-2
Electrostatic discharge
immunity test
immunity test
PASS
Contact discharge up to ±4 kV
Air discharge up to ±8 kV
The performance criteria is B
Air discharge up to ±8 kV
The performance criteria is B
EN 55020:2007
IEC 61000-4-3
IEC 61000-4-3
Radiated, radio-frequency,
electromagnetic field
immunity test
electromagnetic field
immunity test
PASS
900MHz
(duty cycle 1/8 , 217Hz
repetition frequency): 3V/m
The performance criteria is A
(duty cycle 1/8 , 217Hz
repetition frequency): 3V/m
The performance criteria is A
EN 55020:2007
IEC 61000-4-4
IEC 61000-4-4
Electrical fast transient / burst
immunity test.
immunity test.
PASS
±
0.5 kV, ±1 kV(AC Input)
The performance criteria is B
The above equipment has been tested by Telecom Technology Center, and found
compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true
and accurate accounts of the measurements of the sample’s EMC characteristics under
the conditions specified in this report.