ES 150P - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL ES 150P EMC - CB Certificate online

 
Page 7 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
8.6 
Class II equipment and Class II constructions within Class I equipment 
 
Reinforced or double insulation between hazardous 
live parts and accessible parts 
 P 
 
Components bridging reinforced or double insulation 
complying with 14.1 a) or 14.3 
Mains transformer 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 2 
capacitors in series complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with a 
single capacitor complying with 14.2.1 b) 
C03, C04 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
8.7 
This sub-clause is void 
 
8.8 
Double Insulation: the Basic or Supplementary 
insulation > 0.4 mm (mm) ......................................: 
Primary wires are double 
insulated 
 
Reinforced insulation > 0.4 mm (mm)  ...................:   
N/A 
 
Thin sheet insulation used inside the enclosure. 
In Mains transformer 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 dielectric 
 N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 dielectric 
 N/A 
 
Reinforced insulation, two layers each of which meet 
10.3 dielectric 
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 dielectric 
Thin sheet insulation with a 
thickness of 0.10 mm. 
 
8.9 
Primary Wiring: Adequate insulation between 
internal hazardous live conductors and accessible 
parts 
Applies to Class I appliances 
N/A 
 
Secondary Wiring: Adequate insulation between 
internal hazardous live parts and conductors 
connected to accessible parts 
 N/A 
8.10 Class 
II 
Wiring: 
(1) Primary: Double insulation between conductors 
connected to the mains and accessible parts. 
(2) Secondary: Double insulation between 
conductors connected to accessible parts and the 
mains 
Primary wires are double  
insulated. No secondary wires 
can come into contact with 
primary parts. 