ES 150P - JBL Audio EMC - CB Certificate (repair manual). Page 9

Read JBL ES 150P EMC - CB Certificate online

 
Page 6 of 44 
Report No. 707082 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0.5 mR/h) 
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  ....:   
N/A 
 
Emission limits under fault conditions ....................:   
N/A 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
(See appended table) 
 
7.1 
Temperature rises not exceeding specified values, 
any single protective device defeated except those 
of Cl. 7.1 a) and b) 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0.2 A at least 150
o
Mains fuse holder 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
PCB P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
 N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
 P 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
 P 
8.5 
Class I equipment 
 
 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a) 
 N/A 
Page of 57
Display