Report No. 702277
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
J.2
After Table J.1 the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral is not
provided.
N/A
Annex B
Replace NOTE 1 by
In the CENELEC countries listed in IEC 62151, special
national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Norway, CLASS I equipment which is
intended for connection to the building installation via a
non-industrial plug or a non-industrial appliance
coupler, or both and in addition is intended for
connection to other equipment or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the network
terminals and ACCESSIBLE parts, have a marking
stating that the equipment must be connected to an
earthed mains socket -outlet.
The marking text shall be as follows:
"Apparatet skal tilkoples jordet stikkontakt"
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there are
additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text is
identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation forming
part of a component, it shall at least consist of either
- two layers of thin sheet material, each of which shall
pass the electric strength test below, or
- one layer having a distance through insulation of at
least 0.4 mm, which shall pass the electric strength test
below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no distance
through insulation requirement for the insulation
consisting of an insulating compound completely filling
the casing, so that CLEARANCES and CREEPAGE
DISTANCES do not exist, if the component passes the
electric strength test in the accordance with the
compliance clause below and in addition:
N/A