Read JBL DUET (serv.man8) EMC - CB Certificate online
- Page 9 of 51 -
www.nemko.com
Report No.
36648
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1 GENERAL
1.5 Components
—
1.5.1 General
—
Comply with IEC 60950-1 or relevant component
standard
standard
(see appended table 1.5.1)
P
1.5.2
Evaluation and testing of components
Certified components are used
in accordance with their
ratings, certifications and they
comply with applicable parts of
this standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 60950-1
and the relevant component
standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
in accordance with their
ratings, certifications and they
comply with applicable parts of
this standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of IEC 60950-1
and the relevant component
standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
P
1.5.3 Thermal
controls
No thermal controls.
N/A
1.5.4 Transformers
No isolating transformer in the
equipment.
equipment.
N/A
1.5.5 Interconnecting
cables
Speaker interconnecting cables
comply with the requirements
of this standard.
comply with the requirements
of this standard.
P
1.5.6
Capacitors in primary circuits ............................. :
Class III equipment.
N/A
1.5.7
Double insulation or reinforced insulation bridged
by components
by components
Class III equipment.
N/A
1.5.7.1 General
—
1.5.7.2 Bridging
capacitors
—
1.5.7.3 Bridging
resistors
—
1.5.7.4 Accessible
parts
—
1.5.8
Components in equipment for IT power systems
Class III equipment.
N/A
1.6 Power
interface
—
Click on the first or last page to see other DUET (serv.man8) service manuals if exist.