Read JBL DUET (serv.man8) EMC - CB Certificate online
- Page 11 of 51 -
www.nemko.com
Report No.
36648
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
1.7.8
Controls and indicators
Refer below:
—
1.7.8.1
Identification, location and marking ................... :
The function of controls
affecting safety is obvious
without knowledge of language
etc.
affecting safety is obvious
without knowledge of language
etc.
P
1.7.8.2 Colours
............................................................... :
For functional indication a LED
lights when the equipment is
operating.
lights when the equipment is
operating.
P
1.7.8.3 Symbols
............................................................ :
There are no switches in the
equipment.
equipment.
N/A
1.7.8.4
Markings using figures ...................................... :
The function of controls
affecting safety is obvious
without knowledge of language
etc.
affecting safety is obvious
without knowledge of language
etc.
N/A
1.7.9
Isolation of multiple power sources .................... :
Not applicable.
N/A
1.7.10
IT power distribution systems
Class III equipment.
N/A
1.7.11
Thermostats and other regulating devices
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.12 Language
........................................................... :
Instructions and equipment
marking related to safety is
applied in a language which is
acceptable in the country in
which the equipment is to be
sold.
marking related to safety is
applied in a language which is
acceptable in the country in
which the equipment is to be
sold.
—
1.7.13 Durability
The marking withstands
required tests.
required tests.
P
1.7.14 Removable
parts
No removable parts.
N/A
1.7.15 Replaceable
batteries
No battery in the equipment.
N/A
Language ............................................................ :
—
1.7.16
Operator access with a tool ................................ :
Class III equipment.
N/A
1.7.17
Equipment for restricted access locations .......... :
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
2 PROTECTION
FROM
HAZARDS
—
2.1
Protection from electric shock and energy hazards
—
2.1.1
Protection in operator access areas
Refer below:
—
2.1.1.1
Access to energized parts
Class III equipment, powered
from a 15Vac Limited Power
Source (LPS).
from a 15Vac Limited Power
Source (LPS).
N/A
Test by inspection .............................................. :
—