Report No. 116366
TRF No.:IECEN60950_1B
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
3.1.1
Current rating and overcurrent protection
Adequate cross sectional areas
on internal wiring.
on internal wiring.
P
3.1.2
Protection against mechanical damage
Wireways are smooth and free
from edges. Wires are
adequately fixed to prevent
excessive strain on wire and
terminals and avoiding damage
to the insulation of the
conductors.
from edges. Wires are
adequately fixed to prevent
excessive strain on wire and
terminals and avoiding damage
to the insulation of the
conductors.
P
3.1.3
Securing of internal wiring
P
3.1.4
Insulation of conductors
Insulation on internal
conductors is considered to be
of adequate quality and suitable
for the application and the
working voltage involved.
conductors is considered to be
of adequate quality and suitable
for the application and the
working voltage involved.
P
3.1.5
Beads and ceramic insulators
No beads or similar ceramic
insulators on conductors.
insulators on conductors.
N/A
3.1.6
Screws for electrical contact pressure
No electrical screw
connections.
connections.
N/A
3.1.7
Insulating materials in electrical connections
No contact pressure through
insulating material.
insulating material.
N/A
3.1.8
Self-tapping and spaced thread screws
Thread-cutting or space thread
screws are not used for
electrical connections.
screws are not used for
electrical connections.
N/A
3.1.9
Termination of conductors
Not applicable.
N/A
10 N pull test
—
3.1.10
Sleeving on wiring
Sleeves are not used as
supplementary insulation.
supplementary insulation.
N/A
3.2
Connection to an a.c. mains supply or a d.c. mains supply
—
3.2.1
Means of connection ..........................................:
Class III equipment. Unit is not
intended for direct connection
to a mains supply
intended for direct connection
to a mains supply
—
3.2.1.1
Connection to an a.c. mains supply
N/A
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A