DUET II (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL DUET II (serv.man6) EMC - CB Certificate online

IEC 60950-1 (ed.1) 
 
- Page 4 of 8 - 
 
 
www.nemko.com 
Report No.   114383 
 
4.7.201 
Parts for which the glow-wire test cannot be 
carried out, such as those made of soft or foamy 
material, shall meet the requirements specified in 
ISO 9772 for category FH-3 material. The glow-
wire test shall not be carried out on parts of 
material classified at least FH-3 according to ISO 
9772 provided that the sample tested was not 
thicker than the relevant part. 
4.7.201.3 Testing of insulating materials 
Parts of insulating material supporting 
POTENTIAL IGNITION SOURCES shall be 
subject to the glow-wire test of AS/NZS 
60695.2.11 which shall be carried out at 750°C 
The test shall also be carried out on other parts of 
insulating material which are within a distance of 3 
mm of the connection. 
NOTE: Contacts in components such as switch 
contacts are considered to be connections. 
For parts which withstand the glow-wire test but 
produce a flame, other parts above the 
connection within the envelope of a vertical 
cylinder having a diameter of 20 mm and a height 
of 50 mm shall be subjected to the needle-flame 
test. However, parts shielded by a barrier which 
meets the needle-flame test shall not be tested. 
The needle-flame test shall be made in 
accordance with AS/NZS 4695.2.2 with the 
following modifications: 
All materials have suitable flame 
class, no testing required. 
Page of 35
Display