DUET 200 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 13

Read JBL DUET 200 (serv.man3) EMC - CB Certificate online

 
 
- Page 13 of 62 - 
 
 
 Report 
No. 111798 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
 
a) Inherently limited output 
Class III equipment powered by
Limited Power Source. 
Therefore all outputs are 
considered to be limited power.
 
b) Impedance limited output 
 
⎯ 
 
c) Regulating network limited output under normal 
operating and single fault condition 
 
⎯ 
 
d) Overcurrent protective device limited output 
 
⎯ 
 
Max. output voltage (V), max. output current (A), 
max. apparent power (VA)..................................... :
 
⎯ 
 
Current rating of overcurrent protective device (A) 
 
⎯ 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
2.6 
Provisions for earthing and bonding 
⎯ 
2.6.1 
Protective earthing 
Class III equipment. 
2.6.2 Functional 
earthing 
 
⎯ 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
⎯ 
2.6.3.1 General 
 
⎯ 
2.6.3.2 
Size of protective earthing conductors 
 
⎯ 
 
Rated current (A), cross-sectional area (mm
2
), AWG
................................................................................:
 
⎯ 
2.6.3.3 
Size of protective bonding conductors 
 
⎯ 
 
Rated current (A), cross-sectional area (mm
2
), AWG
................................................................................:
 
⎯ 
2.6.3.4 
Resistance of earthing conductors and their 
terminations; resistance (
Ω), voltage drop (V), test 
current (A), duration (min) ......................................:
 
⎯ 
2.6.3.5 Colour 
of insulation.................................................:  
⎯ 
2.6.4 Terminals 
 
 
2.6.4.1 General 
 
 
Page of 62