Page 10 of 38
Report No. : W12-950-062
IEC
60950-1/Am1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
Korea Testing Certification
2.2.1 General
requirements
P
2.2.2
Voltages under normal conditions (V) ................... : Within SELV limits
P
2.2.3
Voltages under fault conditions (V) ....................... : Within SELV limits
P
2.2.4
Connection of SELV circuits to other circuits ...... :
Connect to SELV circuits only
P
2.3 TNV
circuits
N/A
2.3.1
Limits
No TNV circuits.
N/A
Type of TNV circuits ............................................... :
⎯
2.3.2
Separation from other circuits and from accessible
parts
parts
N/A
2.3.2.1 General
requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions ......................... :
N/A
2.3.3
Separation from hazardous voltages
N/A
Insulation
employed ............................................... :
⎯
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation
employed ............................................... :
⎯
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
N/A
2.4.1 General
requirements
No limited current circuits
N/A
2.4.2 Limit
values
N/A
Frequency
(Hz) ...................................................... :
⎯
Measured
current (mA) .......................................... :
⎯
Measured
voltage (V) ............................................. :
⎯
Measured circuit capacitance (nF or µF) ............... :
⎯
2.4.3
Connection of limited current circuits to other
circuits
circuits
N/A
2.5
Limited power sources
N/A
a) Inherently limited output
Approved L.P.S AC/DC
Adaptor used
Adaptor used
N/A
b) Impedance limited output
N/A
c) Regulating network limited output under normal
operating and single fault condition
operating and single fault condition
N/A