CREATURE III (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 5

Read JBL CREATURE III (serv.man6) EMC - CB Certificate online

 
Page 5 of 38
 
Report No. : W12-950-062
 
TRF No. IECEN60950_1C 
 
Korea Testing Certification
 
 
Test item particulars
 ................................................... :  
Equipment mobility..................................................... : [x] movable     [] hand-held       [] transportable 
[] stationary  [] for building-in  [] direct plug-in 
Connection to the mains ............................................ : [] pluggable equipment   [] type A   [] type B 
[] permanent connection 
[] detachable power supply cord      
[] non-detachable power supply cord 
[x] not directly connected to the mains 
Operating condition .................................................... : [x] continuous 
[] rated operating / resting time:  
Access location  ......................................................... : [x] operator accessible 
[] restricted access location 
Over voltage category (OVC)  ................................... : [] OVC I     [x] OVC II     [] OVC III     [] OVC IV 
[x] other: Not directly connected to the mains 
Mains supply tolerance (%) or absolute mains 
supply values  ............................................................ :
Not directly connected to the mains 
Tested for IT power systems  .................................... : [ ] Yes     [x] No 
IT testing, phase-phase voltage (V)  .......................... : N/A 
Class of equipment  ................................................... : [] Class I     [] Class II     [x] Class III      
[] Not classified 
Considered current rating of protective device as 
part of the building installation (A)  ............................ :
N/A 
Pollution degree (PD)  ............................................... : [] PD 1     [x] PD 2     [] PD 3 
IP protection class  .................................................... : IPX0 
Altitude during operation (m)  .................................... : 2000 
Altitude of test laboratory (m)  .................................... : <500m 
Mass of equipment (kg)  ............................................ : 1.6kg 
Possible test case verdicts:
 
 
- test case does not apply to the test object ................. : N/A (or N) 
- test object does meet the requirement....................... : P (Pass) 
- test object does not meet the requirement ................ : F (Fail) 
Testing
 .......................................................................... :  
Date of receipt of test item ............................................ : 2012-11-01 
Date(s) of performance of tests .................................... : From 2012-11-01 to 2012-11-20 
Page of 127
Display

Click on the first or last page to see other CREATURE III (serv.man6) service manuals if exist.