Read JBL CREATURE III (serv.man6) EMC - CB Certificate online
Page 5 of 38
Report No. : W12-950-062
TRF No. IECEN60950_1C
Korea Testing Certification
Test item particulars
................................................... :
Equipment mobility..................................................... : [x] movable [] hand-held [] transportable
[] stationary [] for building-in [] direct plug-in
Connection to the mains ............................................ : [] pluggable equipment [] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[x] not directly connected to the mains
[] detachable power supply cord
[] non-detachable power supply cord
[x] not directly connected to the mains
Operating condition .................................................... : [x] continuous
[] rated operating / resting time:
Access location ......................................................... : [x] operator accessible
[] restricted access location
Over voltage category (OVC) ................................... : [] OVC I [x] OVC II [] OVC III [] OVC IV
[x] other: Not directly connected to the mains
Mains supply tolerance (%) or absolute mains
supply values ............................................................ :
supply values ............................................................ :
Not directly connected to the mains
Tested for IT power systems .................................... : [ ] Yes [x] No
IT testing, phase-phase voltage (V) .......................... : N/A
Class of equipment ................................................... : [] Class I [] Class II [x] Class III
IT testing, phase-phase voltage (V) .......................... : N/A
Class of equipment ................................................... : [] Class I [] Class II [x] Class III
[] Not classified
Considered current rating of protective device as
part of the building installation (A) ............................ :
part of the building installation (A) ............................ :
N/A
Pollution degree (PD) ............................................... : [] PD 1 [x] PD 2 [] PD 3
IP protection class .................................................... : IPX0
Altitude during operation (m) .................................... : 2000
Altitude of test laboratory (m) .................................... : <500m
Mass of equipment (kg) ............................................ : 1.6kg
IP protection class .................................................... : IPX0
Altitude during operation (m) .................................... : 2000
Altitude of test laboratory (m) .................................... : <500m
Mass of equipment (kg) ............................................ : 1.6kg
Possible test case verdicts:
- test case does not apply to the test object ................. : N/A (or N)
- test object does meet the requirement....................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing
.......................................................................... :
Date of receipt of test item ............................................ : 2012-11-01
Date(s) of performance of tests .................................... : From 2012-11-01 to 2012-11-20
Click on the first or last page to see other CREATURE III (serv.man6) service manuals if exist.