Page 12 of 64 Report No. JSH006110064-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table)
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T501 basic insulation
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
T502 basic insulation
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
P
Coil formers and partition walls > 0,4 mm
T501 bobbin: 0.85mm
T502 bobbin: 0.85mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
T501 basic insulation
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
minimum 5.3 mm between
T501 core and primary,
Supplementary insulation
minimum 2.9mm between
T501 core and secondary.
T502 basic insulation
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
minimum 4.2 mm between
T502 core and primary,
Supplementary insulation
minimum 4.2mm between
T502 core and secondary.
P
Coil formers and partition walls > 0,4 mm
T501 bobbin: 0.85 mm
T502 bobbin: 0.85 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A