Read JBL CINEMA 510 (serv.man2) EMC - CB Certificate online
Page 96 of 99
Report No.: 17032772 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
b) The electrical connections are made by using
existing terminals and connections in the apparatus
or the building wiring
existing terminals and connections in the apparatus
or the building wiring
N/A
18
Non-intrinsically protected picture tubes comply with
18.1, 18.2.2 and 18.3. Intrinsically protected picture
tubes with a maximum face dimension exceeding 7.5
cm comply with UL 61965.
18.1, 18.2.2 and 18.3. Intrinsically protected picture
tubes with a maximum face dimension exceeding 7.5
cm comply with UL 61965.
N/A
A bulb of a picture tube having a face diameter of 7.5
cm or more are mounted in an enclosure
cm or more are mounted in an enclosure
N/A
Enclosure opening dimensions
N/A
18.1
All tubes are mounted such that the enclosure of the
apparatus protects the tube against the effects of
implosion.
apparatus protects the tube against the effects of
implosion.
N/A
18.2
Clauses 18.2, 18.2.1 and 18.2.3 are deleted
N/A
19
The tests in 19.1, 19.2 and 19.3 do not cause the
apparatus to overturn.
apparatus to overturn.
N/A
The test in 19.2.1 does not cause the apparatus to
slide
slide
N/A
When polymeric materials are involved, testing is to
be conducted before and after the sub-clause 12.1.5
stress relief test.
be conducted before and after the sub-clause 12.1.5
stress relief test.
N/A
19.1
References to an apparatus in combination with a
supplied cart or recommended stand are deleted
supplied cart or recommended stand are deleted
N/A
19.2
References to an apparatus in combination with a
supplied cart or recommended stand are deleted
supplied cart or recommended stand are deleted
N/A
19.2.1
Slide test
N/A
19.3
Horizontal force stability test using Table 20A values
from UL 60065
from UL 60065
N/A
19.5
Reference to the impact hammer in the first
compliance paragraph is deleted
compliance paragraph is deleted
N/A
19.6
Equipment rack mounting test
N/A
20.1a
Deleted
N/A
20.1b
Exception for parts such as protection TV lenses,
loudspeaker parts, external accessories, and fibrous
materials
loudspeaker parts, external accessories, and fibrous
materials
P
Reference to IEC 60707 replaced by UL 94
P
20.1.2
Sleeving, extruded tubing and insulation on wiring
are rated VW-1:
a) wiring located in a circuit that is considered a
potential ignition source, or
are rated VW-1:
a) wiring located in a circuit that is considered a
potential ignition source, or
P
Click on the first or last page to see other CINEMA 510 (serv.man2) service manuals if exist.