Report No.: 17032772 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
14.11
Component power supplies and their optocouplers
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause.
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause.
N/A
Optocouplers comply with UL 1577
P
Optocouplers bridging reinforced insulation comply
with requirements for double protection as specified
in UL 1577
with requirements for double protection as specified
in UL 1577
P
External clearances and creepage distances of
optocouplers comply with 13.1
optocouplers comply with 13.1
P
14.12
Reference to IEC 61051-2 replaced by UL 1449
No varistor used.
N/A
Reference to IEC 60707 replaced by UL 94
P
All references to IEC 60151 are deleted
N/A
15.1.1
Attachment plug current rating (no less than 125% of
the current drawn under normal operating conditions)
and voltage rating ................................................ :
the current drawn under normal operating conditions)
and voltage rating ................................................ :
(see appended table 14)
P
Configuration and electrical rating of an attachment
plug for apparatus for use on more than one supply
voltage by means of a voltage selector ................ :
plug for apparatus for use on more than one supply
voltage by means of a voltage selector ................ :
N/A
Polarized attachment plug
N/A
Wire gauge of conductors and internal wiring
connecting mains socket-outlets
connecting mains socket-outlets
N/A
15.1.3.1
Means of output connections on an audio amplifier
having an open-circuit audio output voltage not
limited to 120 V that is permanently connected to the
mains
having an open-circuit audio output voltage not
limited to 120 V that is permanently connected to the
mains
Not more than 120V.
N/A
Quick Connect Terminals:
N/A
a) Male tabs firmly mounted in place;
N/A
b) Mating female connectors provided with the
apparatus;
apparatus;
N/A
c) Strain Relief Test of Clause 16.5;
N/A
d) Installation instructions provided for assembly of
terminal to a conductor and strain relief
terminal to a conductor and strain relief
N/A
e) Terminals are appropriate for use with the size
and type of wire specified
and type of wire specified
N/A
15.1.3.2
Audio amplifiers having an audio output not limited to
120 V that are connected to the mains by a flexible
cord
120 V that are connected to the mains by a flexible
cord
N/A
15.2
Cross-sectional area of the earthing conductor in a
supply cord or in an interconnecting cable
supply cord or in an interconnecting cable
N/A