Read JBL CINEMA 510 (serv.man2) EMC - CB Certificate online
Page 11 of 99
Report No.: 17032772 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
a) Test probe 11 of IEC 61032 for 10 s (50 N)
N/A
b) Test hook of fig. 4 for 10 s (20 N)
N/A
c) 30 mm diameter test tool for 5 s (100 or 250 N)
100N
P
9.2
No hazard after removing a cover by hand
No such removable cover.
N/A
10
Insulation requirements
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4
surge test for basic and 4
MΩ min. for reinforced
insulation ............................................................:
No antenna connection.
N/A
10.2
Humidity treatment 48 h or 120 h .........................:
95% R. H., 40
o
C, 120h
(manufacturer requirement)
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
P
11
Fault conditions
P
11.1
No shock hazard under fault condition
(see appended table 11.1)
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
No flames
N/A
No hazard from softening solder
No softening solder
N/A
Soldered terminations not used as protective
mechanism
mechanism
P
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
(see appended table)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
(see appended table)
P
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
N/A
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ............... :
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ............... :
N/A