Report No.: 17032772 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8.17
Insulated winding wire without additional interleaved
insulation
insulation
Approved triple insulated wire
used in transformer TR1, also
see appendix 1. Tube used
when secondary insulated
wires and primary winding
crossing each other at an
angle between 45
used in transformer TR1, also
see appendix 1. Tube used
when secondary insulated
wires and primary winding
crossing each other at an
angle between 45
o
and 90
o
.
P
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Mains plug/coupler used
P
8.19.1
Disconnect device
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
No such mains switch
N/A
8.20
Switch not fitted in the mains cord
Not fitted in the mains cord.
P
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
< 1000 V
N/A
9.1.1.1
a) Open circuit voltages
See appended table for max.
output of SPS.
output of SPS.
P
b) Touch current measured from terminal devices
using the network in annex D ...............................:
using the network in annex D ...............................:
(see appended table 9.1.1)
P
c) Discharge not exceeding 45
μC
< 45
μC
P
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or levers
P
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................:
of the mains plug; voltage (V) after 2 s .................:
Max. 24Vpeak measured after
2 s (limit: 35Vpeak)
2 s (limit: 35Vpeak)
P
If C is not greater than 0,1
μF no test needed
N/A
9.1.7
Resistance to external forces
P