CINEMA 510 (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 11

Read JBL CINEMA 510 (serv.man2) EMC - CB Certificate online

 
 
 
 
Page 10 of 99 
 
 
 
Report No.: 17032772 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
8.17 
Insulated winding wire without additional interleaved 
insulation  
Approved triple insulated wire 
used in transformer TR1, also 
see appendix 1. Tube used 
when secondary insulated 
wires and primary winding 
crossing each other at an 
angle between 45
o
 and 90
 o
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
Mains plug/coupler used 
8.19.1 
Disconnect device  
 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 
N/A 
8.19.2 
Mains switch ON indication  
No such mains switch 
N/A 
8.20 
Switch not fitted in the mains cord  
Not fitted in the mains cord. 
8.21 
Bridging components comply with clause 14  
 
N/A 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
< 1000 V 
N/A 
9.1.1.1 
a) Open circuit voltages  
See appended table for max. 
output of SPS. 
 
b) Touch current measured from terminal devices 
using the network in annex D ...............................: 
(see appended table 9.1.1) 
 
c) Discharge not exceeding 45 
μC  
< 45 
μC 
 
d) Energy of discharge not exceeding 350 mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
9.1.2 
No hazardous live shafts of knobs, handles or levers    
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................: 
Max. 24Vpeak measured after 
2 s (limit: 35Vpeak) 
 
If C is not greater than 0,1 
μF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
 
Page of 108
Display