page 32 of 34 
Ref.No.:414744  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
National differences for Singapore                                                                             
(These differences are taken from IEC 60065:1993 and adopted to IEC 60065:1998)
 
 
IEC 60065: 1998 
Clauses:  4, 7, 9, 10 and 16.                                                                                                              
 
 
Throughout the standard, whenever the words "white pine board" appear, insert  
the words "or plywood board" to it. 
Noted 
 
SS143 Amendment No. 1 and No. 2 
 
4.1.3 
(4.1.3)* 
Delete "45 % to 75 %" and insert 65 ± 5 %. 
75% maximum in IEC 60065: 
1998 
7.1 
(7.1) 
Resistance to heat without external forces. 
Adopt the temperature specified for the tropical 
conditions. 
 P 
8.6 
(9.3.4) 
Delete the note " A Quality Assessment System 
for capacitors complying with Subclause 14.2 is 
under consideration in the IEC". 
This is not in IEC 60065:1998. 
Noted 
10.2 
(10.2) 
Humidity treatment 
Adopt the testing conditions designed for tropical 
conditions. 
 
120h at a relative humidity of 
93% 
16 
(16) 
External flexible cords 
Delete "IEC Publication 60227: Polyvinyl Chloride 
Insulated Cables of Rated Voltages up to and 
Including 450/750 V and IEC publication 60245: 
Rubber insulated Cables of rated up to and 
including 450/750 V " and insert "Singapore 
Standard 236: Flexible Cords", whenever they 
appear in this clause. 
Delete "CEE Publication 13, CEE Publication 2 
and IEC Publication 60173: Colours of the Cores 
of Flexible Cables and Cords" whenever they 
appear in this clause. 
 Noted 
16.2 
(16.2) 
Delete the notes in small print and insert  "A 
nominal cross-sectional area of  0.75 mm² will 
satisfy this requirement". 
This is not in IEC 60065:1998. 
Noted 
 