AUTHENTICS L8 (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 21

Read JBL AUTHENTICS L8 (serv.man4) EMC - CB Certificate online

Report No.: EM201300471-1                       Application No.:
 
ZJ00032008                  Page 21 of 57 
DH3 
time slot= 
1.669  (ms)*  (1600/(4*79)) *
0.5 = 4.225 ms 
DH5 
time slot= 
2.917  (ms)*  (1600/(6*79)) *
0.5 = 4.923 ms 
 
 
 
 
 
 
 
 
 
2DH1 
time slot= 
0.414  (ms)*  (1600/(2*79)) *
0.5 = 2.096 ms 
2DH3 
time slot= 
1.669  (ms)*  (1600/(4*79)) *
0.5 = 4.225 ms 
2DH5 
time slot= 
2.933  (ms)*  (1600/(6*79)) *
0.5 = 4.950 ms 
 
 
 
 
 
 
 
 
 
3DH1 
time slot= 
0.414  (ms)*  (1600/(2*79)) *
0.5 = 2.096 ms 
3DH3 
time slot= 
1.669  (ms)*  (1600/(4*79)) *
0.5 = 4.225 ms 
3DH5 
time slot= 
2.933  (ms)*  (1600/(6*79)) *
0.5 = 4.950 ms 
 
3.  Channel 78: 2.480GHz 
DH1 
time slot= 
0.405  (ms)*  (1600/(2*79)) *
0.5 = 2.051 ms 
DH3 
time slot= 
1.669  (ms)*  (1600/(4*79)) *
0.5 = 4.225 ms 
DH5 
time slot= 
2.917  (ms)*  (1600/(6*79)) *
0.5 = 4.923 ms 
 
 
 
 
 
 
 
 
 
2DH1 
time slot= 
0.405  (ms)*  (1600/(2*79)) *
0.5 = 2.051 ms 
2DH3 
time slot= 
1.669  (ms)*  (1600/(4*79)) *
0.5 = 4.225 ms 
2DH5 
time slot= 
2.933  (ms)*  (1600/(6*79)) *
0.5 = 4.950 ms 
 
 
 
 
 
 
 
 
 
3DH1 
time slot= 
0.405  (ms)*  (1600/(2*79)) *
0.5 = 2.051 ms 
3DH3 
time slot= 
1.669  (ms)*  (1600/(4*79)) *
0.5 = 4.225 ms 
3DH5 
time slot= 
2.917  (ms)*  (1600/(6*79)) *
0.5 = 4.923 ms 
 
The results are not greater than 0.4 seconds. 
The unit does meet the requirements. 
 
Please refer the graph as below: 
Page of 57