Read JBL AUTHENTICS L8 (serv.man2) EMC - CB Certificate online
Report No.: EM201300650-1 Application No.: ZJ00032008 Page 26 of 42
4.4 TRANSMITTER SPURIOUS EMISSIONS
4.5.1 LIMITS
Frequency range
Limit when operating
Limit when in standby
30 MHz to 1 GHz
-36 dBm
-57 dBm
above 1 GHz to 12.75 GHz
-30 dBm
-47 dBm
1.8 GHz to 1.9 GHz
5.15 GHz to 5.3 GHz
-47 dBm
-47 dBm
4.5.2 TEST METHOD
EUT operation status:
Keep EUT on transmitting mode by the software provided by
manufacturer.
Pretest the EUT at different transmission rate and report show
the worst case data.
manufacturer.
Pretest the EUT at different transmission rate and report show
the worst case data.
Test channel:
802.11b/g
Lowest channel: (2412MHz), Highest channel: (2472MHz)
Lowest channel: (2412MHz), Highest channel: (2472MHz)
Test condition:
Normal test conditions.
Test equipment used:
Refer to section 3.4
Test procedure:
1. The EUT shall be performed at the highest power level at
which the transmitter is intended to operate.and Interface
cables, loads, and devices should be connected to at least
one of each type of the interface ports of the EUT and,
where practical, each cable shall be terminated in a device
typical for its actual use. EUT shall be placed at the 1.5m
support on the turntable.
cables, loads, and devices should be connected to at least
one of each type of the interface ports of the EUT and,
where practical, each cable shall be terminated in a device
typical for its actual use. EUT shall be placed at the 1.5m
support on the turntable.
2. The test antenna at a horizontal distance of 3 m .It shall be
raised and lowered from 1m to 4m until a maximum signal
level is detected by the measuring receiver. Then the
turntable should be rotated through 360° in the horizontal
plane, until the maximum signal level is detected by the
measuring receiver. In both the vertical and the horizontal
polarization. Record the reading level, antenna position,
polarization and turntable position.
level is detected by the measuring receiver. Then the
turntable should be rotated through 360° in the horizontal
plane, until the maximum signal level is detected by the
measuring receiver. In both the vertical and the horizontal
polarization. Record the reading level, antenna position,
polarization and turntable position.
3. Remove the transmitter and replace it with a substitution
antenna (the antenna should be half-wavelength for each
frequency involved). The center of the substitution antenna
should be approximately at the same location as the center
of the transmitter. For frequencies of 80 MHz and above, the
dipoles should have their arm lengths set for resonance at
frequency involved). The center of the substitution antenna
should be approximately at the same location as the center
of the transmitter. For frequencies of 80 MHz and above, the
dipoles should have their arm lengths set for resonance at
Click on the first or last page to see other AUTHENTICS L8 (serv.man2) service manuals if exist.