ARRAY 1500 - JBL Audio Service Manual (repair manual). Page 5

Read JBL ARRAY 1500 Service Manual online

Parameter
Specification
Unit
QA Test 
Limits
Conditions
Notes
Transients/Pops
ATO Transient
5 mV-peak
n/a
@ Speaker Output
Turn-on Transient
50 mV-peak
1V-pk-pk @ Speaker Output
AC Line cycled from OFF to ON
Turn-off Transient
50 mV-peak
1V-pk-pk @ Speaker Output
AC Line cycled from ON to OFF
Efficiency
Efficiency
73
%
70
500W of output power into rated 
impedance
Nominal Line voltage 
Stand-by Input Power
2
3
@ nominal line voltage, Amp in 
OFF state, RED LED activated
Maximum allowable  input power LED in RED, 
Class D inactive 
Stand-by Input Power
10
Watts
8
@ nom. line voltage, Amp in On 
state, Green LED activated
Maximum allowable  input power under nominal  
Input voltage and frequency, in stand-by mode 
(HOT or COLD operation, LED GREEN). Class D 
active but no stimulus signal applied.
Power Cons. @ 500W
678
Watts
714
@ nom. line voltage
500 Watts into rated impedance 8 Ohms 
Protection
Thermal Protection 
YES
functional @1/8 max unclipped Power
Temperature rise in accessible metal parts should 
not exceed 35K rise for domestic version or 30K 
sheet). Unit is protected for over-temperature 
conditions 
DC Offset Protection
YES
-
DC present at Speaker Out leads
Relay opens during a DC output condition
Line Fuse Rating
Japan 100V & USA- Versions 
6.3
Amps
Type-T or Slo Blo-250 V
UL, PSE Approved
3.15
Amps
Type-T, Low breaking capacity-250VSEMKO Approved
4
1500 
Array 
Subwoofer 
           
 
 
 
Page of 28
Display

Click on the first or last page to see other ARRAY 1500 service manuals if exist.