ARRAY 1500 - JBL Audio Service Manual (repair manual)

array 1500 service manual
Model
ARRAY 1500
Pages
28
Size
1.78 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
array-1500.pdf
Date

Read JBL ARRAY 1500 Service Manual online

 
  
      
Project Array
  
1500 Array 
Subwoofer
 
Service Manual
         230 Volt 
 
 
 
 
JBL Consumer Products 
250 Crossways Park Dr. 
     Woodbury, New York   11797 
 
 
Rev0  4/2006 
 
 
 
 
 
 
 
-  CONTENTS  - 
 
BASIC SPECIFICATIONS …………….……..…………..1 
PACKING……..……......................................................2 
DETAILED SPECIFICATIONS ……….……..…………..3 
CONNECTIONS………………………...……..…...…..…5 
OPERATION ……..………………….……...…….….…...6 
BASIC TROUBLESHOOTING……………………………7 
EXPLODED VIEW/PARTS LIST…….….….…………....8 
TEST SET-UP AND PROCEDURE….………………….9 
BLOCK DIAGRAM….…………………………………….10 
ELECTRICAL PARTS LIST……………………………..11 
P.C.B. DRAWINGS….……………...........................….16 
IC/TRANSISTOR PINOUTS..……..….…….….….….….22 
SCHEMATICS…………………….………………………23 
 
 
1500 ARRAY SPECIFICATIONS 
 
General 
 
Output 
     1000W 
 
Low-Frequency Transducer   
 
W1500H 15" Pulp-cone driver 
 
Frequency Response (-3dB)   
 
25Hz – 400Hz, variable 
 
Crossover Frequencies  
 
 
40Hz-140Hz HP 
 
Port 
 
     4" 
Flared 
 
Dimensions (H x W x D)  
23" x 19-1/2" x 19" (584mm x 495mm x 483mm) 
21" (533mm) Deep with grille 
 
Weight 
     125 
lb 
(57kg) 
 
 
 
 
JBL continually strives to update and improve existing products, as well as create new ones. The 
specifications and details in this and related JBL publications are therefore subject to change without 
notice. 
1
1500 
Array 
Subwoofer 
           
 
 
 
 
 
                
Ref# Part 
Number Description 
Qty 
 
 
 
 
361041-002  1500 Array Owner’s Manual 
2 331994-001 
JBL 
Warranty 
Card 
361408-001  1500 Array Outer Carton 
354374-001  Packing Foam (Top) 
354374-001  Packing Foam (Bottom) 
6 340805-006 
(Plate) 
Feet 
 
 
 
 
 
 
                  
2
1500 
Array 
Subwoofer 
        
 
 
1500 Array Powered Sub/ Plate Amp 
LINE VOLTAGE
Yes/No
Hi/Lo Line
Nom.
Unit
Notes
US 120VAC/60Hz
YES
108-132
120
Vrms
Normal Operation
EU 230VAC/50-60Hz
YES
207-264
230
Vrms
Normal operation, MOMS required
YES
90-110
100
Vrms
Normal operation, MOMS required
Parameter
Specification
Unit
QA Test 
Limits
Conditions
Notes
Amp Section
Type (Class AB, D, other)
D
n/a
n/a
Bridge type amplifier, None of the speaker terminals 
must be connected to system GND at any time.
Load Impedance (speaker)
8
Ohms
n/a
Nominal
Rated Output Power
650
Watts
593
1 input driven
Test frequency 100 Hz
THD @ Rated Power
0.5
%
1
22K filter
THD @ 1 Watt
0.1
%
0.2
22K filter
Dynamic Power
700
Watts
690
Power is the average measurement 
of the first four consecutive peaks of 
the burst signal
3/20 Cycles @ 50 Hz, burst test into 8 Ohms, input 
driven with  800mV RMS
DC Offset
20
mV-DC
100
@ Speaker Outputs
Damping factor
>20
DF
15
Measured at amplifier board 
Measured at the speaker cable.  500 Watts, 
measured at speaker output terminals located at the
amp board.
Input Sensitivity
Input Frequency
100
Hz
100
Nominal Freq.
Line level input 
11.69
mVrms
±2dB
To 1 Watt
Single input driven, Ap Zo=600 Ohms, LFE mode,   
Volume ctrl. at max.
Signal to Noise
SNR-A-Weighted
100
dBA
95
Relative to rated power (650 Watts) A-Weighting filter
SNR-unweighted
95
dBr
90
Relative to rated power (650 Watts) 22K filter
SNR rel. 1W-unweighted
70
dBr
65
Relative to 1W Output
22K filter
Residual Noise Floor
0.5
mVrms
1
Volume @max, LFE Mode, using 
RMS reading DMM/VOM (or A/P)
Residual Noise Floor
0.5 mVrms(max)
1
Volume @max, LFE Mode, w/ A/P 
Swept Bandpass Measurement 
(Line freq.+ harmonics)
Input Impedance
Line Input 
10K
ohms
n/a
Nominal
Filters
LP  4th order variable 
40-140 Hz
± 10
Subsonic filter (HPF) 3rd Orde
Fixed Hz
± 10
LFE Mode
Fixed Hz
± 10
LP Mode switch at LFE
Features
Line Level output
YES
functional 
RCA Line buffered line level output
Volume pot Taper (lin/log)
LOG
--
functional 
A Taper
Variable crossover 40-140 Hz
YES
functional 
4th Order LP Filter,  2nd order fix and 2nd order 
variable.
LP Selector switch  LFE-
Normal
YES
functional 
Pass through from the speaker input section
Phase switch
YES
--
functional 
Disables LP filter, intended for LFE 
Auto- On-Off  selector
YES
functional 
Switch located at the back panel
Input Configuration
Single Line input 
YES
--
functional 
Single RCA jack (BLK Color)
Line output configuration
Single Line level output
YES
Functional
Gain=0dB respect to line level input, 
Zo=600 Ohms 
Single RCA jack (BLK Color)
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
YES
functional  Auto - on selection switch in Auto 
ATO Input test frequency
50
Hz
functional 
"
ATO Level, Line Input
2.5
mV
functional 
"
ATO Turn-on time
2 seconds
functional 
Amp connected and AC on, then 
input signal applied
Auto Mute/ Turn-OFF Time
15
minutes
17
(T) Time  before muting, after input 
signal is removed
Auto turn of time (T)   must be  10 > T < 17 Minutes
Power on Delay time
ATO mode
4
sec.
5
After applying the minimum ATO voltage (2mVRMS)
ON mode
2
sec.
2
After turning the stand-by knob to ON position
3
1500 
Array 
Subwoofer 
           
 
 
 
Page of 28
Display

Download JBL ARRAY 1500 Service Manual (Repair Manual)

Here you can read online and download JBL ARRAY 1500 Service Manual in PDF. ARRAY 1500 service manual will guide through the process and help you recover, restore, fix, disassemble and repair JBL ARRAY 1500 Audio. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.