Read Harman Kardon GPS 500 EMC - CB Certificate online
<11006065 001>
Page 64 of 71
National Differences
Clause
Requirement
−
Test
Result – Remark
Verdict
Canadian National Differences according to CB Bulletin No. 107A, May 2004
3.4.11
For computer room applications, equipment with
battery systems capable of supplying 750 VA for
five minutes are required to have a battery
disconnect means that may be connected to the
computer room remote power-off circuit.
Not such an application.
N
4.3.12
The maximum quantify of flammable liquid stored
in equipment is required to comply with NFPA 30.
No flammable liquid.
N
4.3.13
Equipment with lasers is required to meet Code of
Federal Regulations 21 CFR 1040 (and the
Canadian Radiation Emitting Devices Act, REDR
C1370).
No laser contained.
N
4.7
For computer room applications, automated
information storage systems with combustible
media greater than 27 cubic feet are required to
have a provision for connection of either
automatic sprinklers or a gaseous agent
extinguishing system with an extended discharge.
Not such an application.
N
4.7.3.1
For computer room applications, enclosures with
combustible material measuring greater than 0.9
m² or a single dimension greater than 1.8 m are
required to have a flame spread rating of 50 or
less. For other applications, enclosures with the
same dimensions require a flame spread rating of
200 or less.
Not such an application.
N
Annex H
Equipment that produces ionizing radiation is
required to comply with the Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
No ionizing radiation.
N
Other differences
1.5.1
Components of equipment must be suitable for
the application, and must comply with the
requirements of the equipment standard and the
applicable national (Canadian and/or U.S.)
component or material standards, as far as they
may apply.
The acceptance will be based on the following:
A component Certified by a Canadian or U.S.
The acceptance will be based on the following:
A component Certified by a Canadian or U.S.
National Certification Body (NCB) to a Canadian
or U.S. component standard will be checked for
correct application and use in accordance with its
specified rating. Where necessary, it will also be
subject to the applicable tests of the equipment
standard.
A component, which has a CB Test Certificate for
A component, which has a CB Test Certificate for
compliance with a relevant IEC component
standard, will be checked for correct application
and use in accordance with its specified ratings.
Where necessary, it will also be subject to the
applicable tests of the equipment standard, and to
Components are UL approved,
see component list 1.5.1.
P