14.3.3 Transformer/motor, 
constructional 
requirements 
Transformer 
Part No. 
Insulation 
between 
Insulation 
Res. M Ohms
Test Volt 
V (60 sec.) 
Clearances / Creepage distances
Measured 
Required 
CLT(
or
 KLT)5I009ZE 
#) 
Pr - Sec 
> 100 
3000 V(rms)
5.2 / 5.2 mm  4.0 / 5.0 mm 
Pr - ic 
> 100 
3000 V(rms)
5.2 / 5.2 mm  4.0 / 5.0 mm 
 
 
 
 
 
 
#) 
Iron core – Sec. = 1.7 mm, therefore iron core to secondary distance is considered to 0 mm. 
- Components 
construction 
CLT(
or
 KLT)5I009ZE
   
Windings on single bobbin.   
The center flange provided between primary and 
secondary windings. Satisfactory constructed. 
Bobbin thickness: > 0.4mm. 
Max. Operating Voltage: 338Vp/239Vrms 
Transformer 
Part No 
Insulation 
Between 
Thick (mm) 
X Number 
Material 
Dielectric strength 
test / 60 sec. 
CLT(or KLT)5I009ZE 
Pr - sec 
0.60 mm min. x 2 
0.70 mm min. x 1 
PBT bobbin flange 
PBT bobbin cap. 
Pass   *) 
Pr - ic 
0.60 mm min. x 1 
PBT bobbin 
Pass      *) 
 
Pr - ic 
0.70 mm min. x 1 
PBT bobbin cap. 
Pass   *) 
 
 
 
 
 
*) Test voltage: 3000 Vrms. 
 