TU 980 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 18

Read Harman Kardon TU 980 (serv.man2) EMC - CB Certificate online

 
 
- Page 14 of 19 - 
 
 
 
 Report 
No. 
133101 
 
 
13 
TABLES: clearances and creepage distances 
Rated supply voltage: 
230 V 
Pollution degree: 
Material Group: 
IIIb 
2 N force on internal parts applied: 
Yes 
30 N force on outside of conductive enclosure applied: 
Yes 
Type of   
Insulation 
Position/ Location 
Operating Voltage 
Clearance (mm) 
Creepage (mm) 
Comm
V peak
V rms
Min 
Actual
Min 
Actual 
Circuits conductively connected to the mains (use Tables 8 and 11): see note below.
 
Basic  Live  Neutral  326 230 2.0 3.8 2.5 3.8 1) 
Reinforced 
Primary 
Secondary 
338 239 4.0 6.4 5.0 6.4 2) 
Reinforced 
Primary 
Secondary 
389 275 4.0 8.4 5.8 8.4 3) 
Reinforced 
Primary 
Secondary 
326 230 4.0 5.0 5.0 5.0 4) 
 
 
 
 
 
 
 
 
 
 
 
1)  Measured on Main pcb before mains fuse (F901).
   
2)  Measured on Main pcb between primary trace and secondary trace. 
3)  Measured on Trans pcb between primary trace and secondary trace.
 
4)  Measured between CN91 connector and near accessible metal chassis (bottom cover). 
 