Read Harman Kardon TU 980 (serv.man2) EMC - CB Certificate online
- Page 14 of 19 -
Report
No.
133101
13
TABLES: clearances and creepage distances
P
Rated supply voltage:
230 V
Pollution degree:
2
Material Group:
IIIb
2 N force on internal parts applied:
Yes
30 N force on outside of conductive enclosure applied:
Yes
Type of
Insulation
Position/ Location
Operating Voltage
Clearance (mm)
Creepage (mm)
Comm
.
1
2
V peak
V rms
Min
Actual
Min
Actual
Circuits conductively connected to the mains (use Tables 8 and 11): see note below.
Basic Live Neutral 326 230 2.0 3.8 2.5 3.8 1)
Reinforced
Primary
Secondary
338 239 4.0 6.4 5.0 6.4 2)
Reinforced
Primary
Secondary
389 275 4.0 8.4 5.8 8.4 3)
Reinforced
Primary
Secondary
326 230 4.0 5.0 5.0 5.0 4)
1) Measured on Main pcb before mains fuse (F901).
2) Measured on Main pcb between primary trace and secondary trace.
3) Measured on Trans pcb between primary trace and secondary trace.
3) Measured on Trans pcb between primary trace and secondary trace.
4) Measured between CN91 connector and near accessible metal chassis (bottom cover).