Read Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate online
- Page 14 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
IEC/EN 60950-1
Clause
Requirement + Test
Result – Remark
Verdict
1.7.13 Replaceable
batteries .......................................... :
N/A
Language(s)
........................................................ :
—
1.7.14
Equipment for restricted access locations ............ :
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
2
PROTECTION FROM HAZARDS
2.1
Protection from electric shock and energy hazards
2.1.1
Protection in operator access areas
Class III equipment.
—
2.1.1.1
Access to energized parts
Class III equipment, supplied
from a LPS.
from a LPS.
N/A
Test by inspection .................................................. :
N/A
Test with test finger (Figure 2A) ............................ :
N/A
Test with test pin (Figure 2B) ................................ :
N/A
Test with test probe (Figure 2C) ............................ :
No TNV circuit in the
equipment.
equipment.
N/A
2.1.1.2
Battery compartments
No TNV circuits in the
equipment.
equipment.
N/A
2.1.1.3
Access to ELV wiring
No internal wiring at ELV
accessible to the operator.
accessible to the operator.
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
N/A
2.1.1.4
Access to hazardous voltage circuit wiring
Class III equipment.
N/A
2.1.1.5 Energy hazards ..................................................... :
Class III equipment, supplied
from a LPS.
from a LPS.
N/A
2.1.1.6 Manual
controls
No
shafts of knobs etc.
N/A
2.1.1.7
Discharge of capacitors in equipment
Class III equipment.
N/A
Measured voltage (V); time-constant (s) ................ :
—
2.1.1.8
Energy hazards – d.c. mains supply
Not connected to DC mains
supply.
supply.
N/A
a) Capacitor connected to the d.c. mains supply .. :
N/A
b) Internal battery connected to the d.c. mains
supply .................................................................... :
supply .................................................................... :
N/A
2.1.1.9 Audio
amplifiers ..................................................... :
Accessible terminal is SELV
only.
only.
P
2.1.2
Protection in service access areas
Class III equipment, SELV
circuit only
circuit only
N/A
2.1.3
Protection in restricted access locations
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
Click on the first or last page to see other SOUNDSTICKS III (serv.man2) service manuals if exist.