 Report 
No. 
158002 
 
 
TRF No.:IECEN60950_1C 
 
 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
”(See Enclosure #)” refers to additional information appended to the report. 
”(See appended table)” refers to a table appended to the report. 
Note: This TRF includes EN Group Differences together with National Differences and Special 
National Conditions, if any.  All Differences are located in the Appendix to the main body of this TRF.
 
Throughout this report a point is used as the decimal separator. 
General product information:
  
 
The EUT is a computer stereo system powered by a detachable certified limited power source adapter with 
a specialized input connector. The adaptor refer to list of critical components.  
 
The EUT is provided with an HB (Flame class) enclosure.  
 
Maximum recommended ambient (Tmra) for product: 25°C 
 
Circuit characteristics: No connection to mains, the equipment contains secondary (SELV). 
 
Normal load:  
Supplied with 1KHz(Satellite) and 100Hz(Subwoofer) sinusoidal input signal in computer speaker system, 
tested by 1/8 non-clipped output power, if not specified. 
 
Model Difference:  
The model SoundSticks III is identical with SoundSticks II except for the color of the power indicator LED. 
 
1.1.2 - Additional requirements: 
Exposure to extreme temperatures, excessive dust, moisture or vibration; to flammable gases; to corrosive 
or explosive atmospheres: 
This equipment is intended to operate in a "normal" environment (Offices and homes). 
 
Electromedical equipment connected to the patient: 
This equipment is not an electromedical equipment intended to be physically connected to a patient. 
 
Equipment used in vehicles, ships or aircrafts, in tropical countries, or at elevations > 2000m: 
This equipment is intended to operate in a "normal" environment (Offices and homes). 
 
 