SB 35 Sabre (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 3

Read Harman Kardon SB 35 Sabre (serv.man2) EMC - CB Certificate online

Page 3 of 41 
Report No.: ACSCBAV13005
 
 
TRF No. IEC60065K 
 
List of Attachments (including a total number of pages in each attachment):  
Attachment 1: European Group Differences (15 pages) 
Attachment 2: National Deviations: Australia/New Zealand, Korea, MALAYSIA, Japan (15 pages) 
Attachment 3: Manufacturer’s Declaration (2 pages) 
Attachment 4: Photographs (12 pages)  
Attachment 5: Diagrams (4 pages) 
Attachment 6: Schematics + PWB Layout (5 pages) 
Summary of testing:  
1)  The sample tested complies with the requirements of the test specification. 
2)  Soundbar (SABRE SB35CNTR) and Subwoofer (SABRE SB35SUB) were evaluated respectively. 
3)  As for Power Transformer (T541) in power supply board of Subwoofer (SABRE SB35SUB), multi 
factories will produce them as alternative use. Since it was same to each other on construction and 
electrical characteristics, the difference of factory did not affect safety aspects.  
Unless otherwise specified, all tests were conducted on the following transformer as representative. 
T541:  Huizhou Sunshine Electronics Co., Ltd. / BCK-AL140 
4)  Following symbols and abbreviations are used in this test report. 
S/C= Short-Circuit 
 
O/C= Open-Circuit 
NH= No Hazard Occurred 
NFR= No Further Results existed 
NB= No breakdown                      NCD= No component damaged 
PCB= Printed Circuit Board 
* = Determined by the method specified in Note f to Table 3. 
Tests performed (name of test and test clause):
Marking durability test (5) 
Input test (5.1) 
Heating test (7.1) 
Touch current (9.1.1) 
Withdrawal of mains plug test (9.1.6) 
Humidity test (10.2) 
Insulation resistance and dielectric strength test 
(10.3) 
Fault condition test (11.1) 
Heating test under fault condition (11.2) 
Impact test (12.1.3) 
Stress relief test (12.1.5) 
Determination of operating voltage (13.2) 
Screw securement test (17.1) 
Stability test (19.1) 
Wall or ceiling mounting means test (19.6) 
Testing location:  see page 2 (Testing procedure 
and testing location) 
Summary of compliance with National Differences 
List of countries addressed: EU, AU, NZ, KR, MY, JP
 
SG (no national differences in CB-Bulletin) 
 
 The product fulfils the requirements of _ IEC 60065: 2001 (Seventh Edition) + A1: 2005 + A2: 2010/ 
EN 60065: 2002 (Seventh Edition) + A1: 2006  + A11: 2008 + A2: 2010 + A12: 2011
 