SB 30 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 41

Read Harman Kardon SB 30 (serv.man2) EMC - CB Certificate online

Report No:W-N-1109009-CY-01-1                                                                                       
Telecom Technology Center 
 
37 
6.7 ELECTROSTATIC DISCHARGE 
st Sp
 
rd: 
IEC 61000-4-2 
6.7.1 Te
ecification
 
Basic Standa
 
Discharge Impedance: 
 
330 ohm / 150 pF 
Discharge Voltage: 
Air Discharge:2kV/4kV/8 Kv (Direct) 
Contact Discharge:2kV/4kV (Direct/Indirect) 
Polarity:   
Positive & Negative 
Number of Discharge: 
Air Discharge: min. 10 times at each test point 
Contact Discharge: min. 25 times at each test point 
Discharge Mode: 
Single Discharge 
Discharge Period: 
 
1 second minimum
 
 
6.7.2 Test Procedure 
 
he test generator necessary to perform direct and indirect application of discharges 
 the EUT in the following manner: 
. Contact discharge was applied to conductive surfaces and coupling planes of the 
UT. 
 t
th single discharges. For the single discharge 
 suc
le discharges was at least 1 second. The EUT shall be 
to a
discharges, 100 each at negative and positive polarity, at a 
st points shall be subjected to at least 50 
er of the front edge of the horizontal coupling plane. 
 receive at least 50 direct contact 
discharges. 
If no direct contact test points are available, then at least 200 indirect discharges 
shall be applied in the indirect mode. Test shall be performed at a maximum 
repetition rate of one discharge per second.   
The selected point, which was performed with electrostatic discharge, please 
refers to the “Photo(s) shown the location(s) of ESD evaluated”. 
Vertical Coupling Plane (VCP): 
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and 
positioned at a distance 0.1m from, the EUT, with the Discharge Electrode 
touching the coupling plane. 
The four faces of the EUT will be performed with electrostatic discharge. 
Horizontal Coupling Plane (HCP): 
The coupling plane is placed under to the EUT. The generator shall be positioned 
vertically at a distance of 0.1m from the EUT, with the Discharge Electrode 
touching the coupling plane. The four faces of the EUT will be performed with 
electrostatic discharge. 
b. Air discharges at insulation surfaces of the EUT. 
It was at least ten single discharges with positive and negative at the same selected 
point. 
c. For the actual test configuration, please refer to the related Item –EUT Test Photos.
 
T
to
a
E
During the est, it was performed wi
time 
between
cessive sing
exposed 
minimum of four test points. One of the te
t least 200 
indirect discharges to the cent
The remaining three test points shall each
Page of 60