Read Harman Kardon SB 26 (serv.man3) EMC - CB Certificate online
Page 18 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
a) Comply with 13.6 (jointed insulation) and N.2.1
Pass
b) Comply with IEC 60747-5-5: 2007
N/A
Alternative to a) and b) optocoupler comply with 13.8
N/A
14.12
Surge suppression varistors
RV501
Pass
Comply with IEC 61051-2
See appended table 14.
Across the line, protected by
fuse-link, F501.
Across the line, protected by
fuse-link, F501.
Pass
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
except for earthed parts of permanently connected
apparatus
Pass
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A
15 Terminals
-
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
and mains socket-outlet meet the appropriate
standard
See appended table 14.
Pass
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
N/A
15.1.2
Connectors for antenna, earth, audio, video or
data
data
Pass
No risk of insertion in mains socket-outlets
Pass
No risk of insertion into audio- or video- outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
not compatible with household mains socket-outlets
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus.
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord provided
with separate protective earth terminal near mains
input
with separate protective earth terminal near mains
input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
Ω at 25 A ...................: N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
For SB26 CNTR: Not directly
connected to the mains.
For SB26 SUB: Detachable
power supply cord.
connected to the mains.
For SB26 SUB: Detachable
power supply cord.
N/A
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N/A