HS 500 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 71

Read Harman Kardon HS 500 (serv.man2) EMC - CB Certificate online

 
 
Report No. JSH006030498-001 
Page 70 of 82  
19.2 Block diagram of test setup 
 
 
 
       
The E
plane, an
          The
supply cable as specified by the EUT manufacturer. 
 
       19.3.1.1  Photo for test set-up 
                  none 
 
19.3.2 Test Procedure 
 
The EUT was tested for each selected combination of test level and duration with a sequence of 
three  dips/interruptions with intervals of 10 s minimum. Each representative mode of operation was 
tested. 
 
EUT is tested for voltage dips of 100%Ut, 0.5 period, 40%Ut,10 periods and 70%Ut,50 periods, 
for  
100%Ut, both the positive and negative polarity test was conducted. 
 
Abrupt changes in supply voltage was occur at zero crossings of the voltage and at additional 
angles  
considered critical by product committees or individual product specifications preferably selected  
from 45
°,90°, 135°, 180°, 225°, 270°,315°. 
 
 
 
19.4 Test Protocol 
 
Temperature  
23
°C  
Relative Humidity 
34%
 
 
 
 
 
 
 
19.3 Test Setup and Test Procedure 
19.3.1 Test setup 
UT was placed on an insulating support of 0.8m height, standing on a ground reference 
d arranged and connected to satisfy its functional requirement 
 test was performed with the EUT connected to the test generator with the shortest power  
GRP 
 
MC 
 
     
EUT 
Best E
Page of 83